Electromagnetism, Capacitors and Induction

Electromagnetism and induction equipment supports demonstrations of magnetic fields, capacitors, and electromagnetic principles.

Designed for clarity and durability, these tools enhance understanding of advanced physics concepts.

Australian schools and universities use this equipment for effective STEM instruction.

11-Step Capacitor Set, 100 pF to 0.47 µF, 350 V AC Rated

  • 11 fixed capacitor values, no switches, step selection by patching circuits with 4 mm banana sockets.
  • Values from 100 pF to 0.22 µF cover pF, nF, µF ranges for filters, timing, resonance, and reactance practicals.
  • Rugged metal housing supports classroom and workshop handling, keeps components protected and organised.
  • Individual sockets allow easy series and parallel combinations to create custom capacitance totals for experiments.
  • Rated to 350 V AC or DC, suitable for higher-voltage training circuits within specified limits.

$184.50 (Ex GST)
Add to cart

Adjustable Aepinus Air Capacitor, 200/283 mm Square Plates, 2–250 pF Range

  • Adjustable air capacitor with two interchangeable square plate sets, quick change design, no loose parts.
  • Magnetic plate alignment keeps plates parallel and true within friction slider blocks for stable measurements.
  • Plate spacing adjustable 1–120 mm, capacitance approximately 300 pF down to 2 pF.
  • Built-in protection prevents circuit issues if plates accidentally touch during adjustment.
  • 4 mm sockets for each plate, sturdy feet for stable bench positioning during experiments.

$323.50 (Ex GST)
Add to cart

Air Cored Inductance Coils, Laboratory Inductor Type

  • Air cored inductance coils for laboratory and classroom electrical demonstrations
  • Matched to the coil format used with small demonstration transformer and induction kit setups
  • Available inductance values include 5 mH, 10 mH, 15 mH and 20 mH
  • Number of turns is adjusted to provide the stated inductance value for each coil
  • Two 4 mm banana sockets are integrated into the coil body for quick connections
  • Consistent coil design supports repeatable inductance and electromagnetic induction demonstrations
  • Each coil is supplied as a single component, with the required mH value selected by the user

From $56.50 (Ex GST)
Select optionsThis product has multiple variants. The options may be chosen on the product page

Air-Cored Solenoid Coil, 700 Turns, 5 A Copper Wire (PSSC)

  • Moulded plastic bobbin air-core solenoid for known magnetic field strength in teaching and calibration setups.
  • Use over magic eye tube for mass of electron experiment, also IEC current balance apparatus construction.
  • For IEC hall effect apparatus calibration when a repeatable magnetic field of known strength is required.
  • 700 turns copper wire winding, carries about 5 A maximum current for strong, stable field generation.
  • 150 mm length, 37 mm bore, inward 4 mm socket terminals allow flat bench placement at ends.

$165.90 (Ex GST)
Add to cart

Capacitor Box, Decade Capacitance Type

  • Rotary capacitor selection boxes for laboratory and classroom circuit experiments
  • Decade models use 10 steps per dial for controlled capacitance selection
  • Available total capacitance options include 1.11 µF, 11.1 µF and 11.11 µF
  • Step sizes include 0.001 µF, 0.01 µF and 1 µF depending on the selected model
  • Single-dial discrete model provides 12 capacitance positions from 220 pF to 1.0 µF
  • Voltage ratings include 400 V DC or 250 V DC and 150 V AC depending on model
  • 4 mm spin-free terminals and extra earthing terminal support practical circuit connection

From $183.50 (Ex GST)
Select optionsThis product has multiple variants. The options may be chosen on the product page

Constant-Current Capacitor Charging Apparatus with Power Supply Included

  • Calculates capacitance in µF using constant-current charging and first-principles measurements.
  • Very small charging current is set then held constant throughout the charge period for clean analysis.
  • Capacitor voltage monitored with high-impedance DVM, 10 MΩ input resistance specified.
  • Student uses stopwatch timing, linking current, time, and voltage to determine capacitance value.
  • Compact 9 V battery supply, typical currents under 1 mA, supports long battery life in class use.

$126.90 (Ex GST)
Add to cart

Dissectible Transformer Kit with Spot Weld Module and Full Accessory Set Included

  • 35 × 35 mm iron core, “U” and clamped “I” section to close magnetic circuit.
  • Mains primary coil with on/off switch, removable mains cable, standard teaching configuration.
  • Tapped low-voltage secondary coil, heavy-current output for practical transformer experiments.
  • Includes spot welder and heavy copper ring for induction heating, wax or solder melting demos.
  • Glass-filled nylon coil formers, heat resistant, unbreakable design, Thompson’s ring included.

$1,043.50 (Ex GST)
Add to cart

Electromagnet, Soft Iron U Core with Dual Coils and 4 mm Terminals

• Soft iron U-core electromagnet, large size, 10 cm overall length, hands-on classroom demonstrator.
• Two copper wire coils supplied, fit over core legs, create strong U-shaped magnetic circuit for practical lessons.
• Two 4 mm captive terminals, fast connection with standard lab leads to low-voltage DC supply.
• Operates on 4.5–6 V, suitable for low-voltage magnetism force and attraction demonstrations on the bench.
• Complete kit includes U-core plus coils plus terminals, ready for student experiments and reliable repeat use.

$49.50 (Ex GST)
Add to cart

Electromagnetic Induction Demonstrator with Rotating Wire and Rod Magnet

  • Single-turn heavy wire loop rotated by hand around strong rod magnet for core induction demonstrations.
  • Loop cuts magnetic field, generates very small induced voltage detectable with a very sensitive meter.
  • Demonstrates conductor cutting magnetic lines of force, fundamental electromagnetic induction theory.
  • Includes a built-in “mystery” teaching prompt for student discussion during experiments and lessons.
  • Optional IEC DC amplifier LB0071-001 boosts small current for reading on student mA bench meters.

$319.90 (Ex GST)
Add to cart

Electrostatic Pith Balls, Laboratory Charge Study Model

  • Electrostatic pith balls for classroom demonstrations, available as plain or conductive coated sets
  • Approx 8 mm diameter, light mass supports visible attraction, repulsion and charge transfer behaviour
  • Plain option supplied as pack of 12, general ball shape, not fully round as described
  • Conductive option supplied as pack of 10, surface coated with conductive paint for experiment use
  • Suitable for electrostatic investigations using charged rods, electroscopes or induction setups where ball motion
  • indicates field effects

From $12.50 (Ex GST)
Select optionsThis product has multiple variants. The options may be chosen on the product page

Oersted’s Law Demonstrator, Current and Magnetic Needle Deflection Apparatus

  • Oersted’s law demonstrator, shows magnetic effect of current in straight wire on needle deflection.
  • Wire path over or under needle, reverse current direction, observe field direction change clearly.
  • Aluminium frame with permanent magnetic needle on sensitive agate bearing, smooth low-friction movement.
  • Sturdy base with binding posts, stable setup for repeatable electricity and magnetism practicals.
  • Needle length noted as 75 mm or 15 cm in supplied info, confirm model specification before purchase

$37.50 (Ex GST)
Add to cart

Transformer 240V AC to 12V AC 12A ,Triple Output Terminals

  • 220/240 V to 12 V AC transformer, supplies three separate low-voltage circuits from one mains unit.
  • Total load up to 12 A across all outputs, suitable for multiple 12 V AC classroom devices.
  • Three output pairs on 4 mm spin-free IEC terminals, easy wiring to three independent circuits.
  • Designed to run up to three Hodson light boxes or similar 12 V AC equipment as specified.
  • Fixed mains cable, non-removable lead, simple plug-in operation for lab benches and classrooms.

$267.90 (Ex GST)
Add to cart
,

Wimshurst Machine for Electrostatic Charge

  • Demonstrates electrostatic charge generation, storage and visible discharge for physics education.
  • Hand crank rotates twin plates in opposite directions to build static electricity.
  • Leyden jar capacitors store charge before spark discharge between terminals.
  • Mounted on a wooden base with rubber feet for stable classroom use.
  • Compact demonstration size with 300 × 180 mm base and 300 mm height.
  • Suitable for supervised lessons on electrostatics, induction, capacitance and electrical discharge, as students observe charge separation and transfer safely during guided classroom experiments.

$174.50 (Ex GST)
Add to cart
,

Wimshurst Machine Spare Belts, Replacement Belt Set

  • Replacement belts for compatible Wimshurst machine demonstrations
  • Suitable for LC-80-EM1641-01 Wimshurst machine
  • Used to support plate rotation during electrostatics experiments
  • Approximate belt circumference is 45 cm
  • Suitable for approximately 140 mm diameter belt path
  • Available as spare belt only or spare belt pair
  • For laboratory or educational use under appropriate supervision

From $12.50 (Ex GST)
Select optionsThis product has multiple variants. The options may be chosen on the product page

didn't see what you are looking for ?

We’ll source it or make it for you.
LabChoice supports your research every step.

Electromagnetism, Capacitors and Induction equipment is designed to support practical teaching and demonstration of core electrical and magnetic principles in physics classrooms, laboratories, and training environments. This category includes capacitor sets, air capacitors, inductance coils, solenoids, transformer kits, electromagnets, induction demonstrators, electrostatic models, and related experimental apparatus used to explore charge, capacitance, inductance, magnetic fields, and electromagnetic induction.

These products enable hands-on experiments covering key physics concepts such as capacitance variation, charge storage, electric field behaviour, magnetic field generation, electromagnetic induction, transformer operation, and current-induced magnetic effects. Equipment such as capacitor boxes and adjustable air capacitors support capacitance studies, while coils, solenoids, and electromagnets allow investigation of magnetic fields and inductive behaviour. Demonstration tools like Oersted’s law apparatus and Wimshurst machines provide clear visual understanding of current and electrostatic phenomena, making them suitable for structured teaching and laboratory demonstrations.

For quality and compliance reference, IEC 61010-1 is a current international standard covering safety requirements for electrical equipment used in measurement, control, and laboratory environments, supporting safe operation during experiments. IEC 60252-1 is applicable for AC motor capacitors and provides a recognised reference for capacitor construction and performance principles relevant to educational capacitor demonstrations. IEC 61558-2-6 is also a current standard covering safety of transformers, reactors, power supply units, and similar equipment, which is relevant for transformer-based teaching kits and power modules used in laboratory environments. These standards should be referenced only where supported by the manufacturer’s technical specifications and compliance documentation.

For LabChoice Australia customers, Electromagnetism, Capacitors and Induction products provide reliable, education-focused solutions for teaching electrical and magnetic principles through hands-on experimentation. They support clear concept understanding across school, university, and technical training environments where visual demonstration and practical learning are essential.