



pH/Conductivity Meter Kit PC910 Benchtop Dual-Channel, 0.00 to 14.00 pH, 0 to 200 mS/cm
AUD 1,475.00(Ex GST)
AUD 1,475.00(Ex GST)
- Dual-channel benchtop meter kit designed for simultaneous pH / mV and conductivity-related measurement workflows
- Suitable for laboratories that need pH, ORP, conductivity, TDS, salinity, resistivity and temperature testing from one bench instrument
- Plain-language menus and graphic screen prompts help reduce training time for routine laboratory users
- GLP data management supports manual and automatic logging with calibration records, time stamps and USB export
- Flexible calibration options support standard buffers, conductivity standards and user-defined calibration workflows
- Complete kit includes PC910 pH / Conductivity Meter, LabSen® 211 Glass pH Combination Electrode, MP500 Temperature Electrode, 2301T-F Conductivity Electrode, 602 Flexible Electrode Holder, pH 4.00 / 7.00 / 10.01 Buffers, 84 µS / 1413 µS / 12.88 mS Conductivity Calibration Solutions, USB Cable, PC-Link 9500 Flash Drive, 9V Adapter and User Manual
- Description
- Specifications
- Datasheets & Manuals
Description
pH/Conductivity Meter Kit PC910 Benchtop Dual-Channel, 0.00 to 14.00 pH, 0 to 200 mS/cm, also known as a dual-channel benchtop pH and conductivity meter kit, is designed for laboratories that need simultaneous pH / mV and conductivity-related measurement from one bench instrument.
This kit is suitable for education, water-quality testing, quality control, research support and routine laboratory workflows where pH, ORP, conductivity, TDS, salinity, resistivity and temperature readings need to be measured, logged and exported.
The PC910 uses an advanced interface with plain-language menus and graphic screen prompts. This helps reduce operator training time and supports more consistent use in shared laboratory environments.
The pH channel includes a LabSen® 211 glass pH combination electrode and MP500 temperature electrode. The LabSen® 211 electrode features a low-impedance glass membrane, long-life reference system and TRIS buffer compatibility, while the MP500 supports 0–100°C automatic temperature compensation.
The conductivity channel includes a 2301T-F conductivity electrode with ATC and K = 1.0 cell constant. The firm platinum black sensor supports conductivity measurement across the listed 0 to 200 mS/cm range, with one-tap switching among conductivity, TDS and salinity.
The meter supports 1–3 point pH calibration and 1–4 point conductivity calibration, with standard buffers, standard conductivity solutions and user-defined calibration options. Automatic electrode slope display and calibration self-diagnosis help users review calibration quality and electrode condition.
GLP data management supports manual and automatic logging of up to 200 data sets, including calibration records and time stamps. USB export to PC helps users manage measurement records for reporting, review and laboratory documentation.
Included with this pH / Conductivity Meter Kit: PC910 pH / Conductivity Meter, 602 Flexible Electrode Holder, LabSen® 211 Glass pH Combination Electrode, MP500 Temperature Electrode, 2301T-F Conductivity Electrode, pH 4.00 Buffer, pH 7.00 Buffer, pH 10.01 Buffer, 84 µS Conductivity Calibration Solution, 1413 µS Conductivity Calibration Solution, 12.88 mS Conductivity Calibration Solution, USB Cable, PC-Link 9500 Flash Drive, 9V Adapter and User Manual.
Users should follow correct calibration, rinsing, electrode storage and data export procedures to support reading stability, electrode service life and reliable record keeping. Electrode selection should be confirmed for specialised pH samples, high-range conductivity or high-purity water testing.
LabChoice Australia supplies pH / Conductivity Meter Kits for schools, universities, laboratories, QC teams and water-quality users requiring dual-channel benchtop measurement with GLP data storage, USB export and flexible electrode compatibility.
Features
- PC910 benchtop pH / conductivity meter kit
- Dual-channel simultaneous measurement
- pH measuring range: 0.00 to 14.00 pH
- Conductivity range: 0 to 200 mS/cm
- Conductivity accuracy: ±1% F.S.
- Measures pH
- Measures mV / ORP
- Measures conductivity / EC
- Measures TDS
- Measures salinity
- Measures resistivity
- Measures temperature
- Advanced plain-language menu interface
- Graphic screen prompts
- Multi-language support: English, German, Spanish and Chinese
- Manual data logging
- Automatic data logging
- GLP-compliant data storage
- Stores up to 200 data sets
- Stores calibration data and time stamps
- USB data export to PC
- LabSen® 211 glass pH combination electrode included
- Low-impedance glass membrane
- Long-life reference system
- Compatible with TRIS buffers
- MP500 temperature electrode included
- 0–100°C ATC support via MP500 temperature probe
- 1–3 point automatic pH calibration
- pH standard buffer recognition: 1.68, 4.00, 7.00, 10.01 and 12.45
- Supports user-defined pH calibration standards
- Automatic electrode slope display
- Calibration self-diagnosis
- Standard BNC pH connector
- RCA temperature connector
- NTC 30KΩ temperature connector compatibility
- Compatible with Swiss LabSen electrodes for specialised sample applications
- 2301T-F conductivity electrode included
- 2301T-F conductivity electrode with ATC
- Conductivity electrode cell constant: K = 1.0
- Firm platinum black conductivity sensor
- 1–4 point automatic conductivity calibration
- Conductivity standard recognition: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm
- Supports user-defined conductivity calibration standards
- One-tap switching among conductivity, TDS and salinity
- Multiple salinity modes: general salinity, saltwater salinity and NaCl salinity
- Standard BNC conductivity connector
- Compatible with 2310T-F electrode for up to 2000 mS/cm applications
- Compatible with DJS-0.1-F electrode for high-purity water applications
- 602 flexible electrode holder included
- pH 4.00 buffer included, 50 mL
- pH 7.00 buffer included, 50 mL
- pH 10.01 buffer included, 50 mL
- 84 µS conductivity calibration solution included, 50 mL
- 1413 µS conductivity calibration solution included, 50 mL
- 12.88 mS conductivity calibration solution included, 50 mL
- USB cable included
- PC-Link 9500 flash drive included
- 9V adapter included
- User manual included
- Calibration routine, electrode selection, salinity mode, ATC setup, PC export requirements and sample compatibility should be confirmed before use
Warranty
The instrument is covered for defects in material and workmanship for three years, while the probe is covered for six months from delivery, subject to the manufacturer’s warranty terms.
The limited warranty does not cover issues caused by accidental damage, improper use, normal wear and tear, transport, storage, failure to follow product instructions, unauthorised maintenance, unauthorised modification, unauthorised repair, incompatible use with other products or materials, abuse, accidents or external causes beyond reasonable control.
Parameter Settings Menu
| Parameter Menu | Options | Factory Default |
|---|---|---|
| 1.0 pH | ||
| 1.1 pH Buffer Selection | CH / USA / NIST / User | USA |
| 1.2 Resolution | 0.01 / 0.1 | 0.01 |
| 1.3 Last Calibration Data | View | – |
| 1.4 Restore Factory Default | Yes / No | No |
| 2.0 Conductivity / TDS | ||
| 2.1 Cell Constant | 10 / 1.0 / 0.1 | 1.0 |
| 2.2 CAL Solution Selection | Standard / CN / User | Standard |
| 2.3 Last Calibration Data | View | – |
| 2.4 Reference Temperature | 15–30 °C | 25 °C |
| 2.5 Temp Compensation Factor | 0.00–10.00% | 2.0% |
| 2.6 TDS Factor | 0.40–1.00 | 0.71 |
| 2.7 Restore Factory Default | Yes / No | No |
| 3.0 Configuration | ||
| 3.1 Reading with HOLD | On / Off | – |
| 3.2 Auto Timing Data Log | Manual / Automatically | Manual |
| 3.3 Temperature Unit | °C / °F | – |
| 3.4 Delete Saved Data | Yes / No | No |
| 3.5 Language Selection | English / Deutsch / Español / Chinese | – |
| 3.6 Date Format | Y-M-D | – |
| 3.7 Time Format | 24-hour / 12-hour | – |
| 3.8 Date Setting | YYYY-MM-DD | – |
| 3.9 Time Setting | HH:MM:SS | – |
What’s in the Kit?
| Item | Quantity |
|---|---|
| PC910 pH/Conductivity Meter | 1 |
| 602 Flexible Electrode Holder | 1 |
| LabSen 211 Glass pH Combination Electrode | 1 |
| MP500 Temperature Electrode | 1 |
| 2301T-F Conductivity Electrode (ATC, K=1.0) | 1 |
| pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) | 3 |
| Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) | 3 |
| USB Cable | 1 |
| PC-Link 9500 Flash Drive | 1 |
| 9V Adapter | 1 |
| User Manual | 1 |
Specifications
Datasheets & Manuals
Document :
Product Information Sheet(Pdf)
LED 3D Shaker with Fixed Plate, 10° Tilt Angle, 10-80 rpm
Magnetic Stirrer, 5 Inch, up to 20 L Capacity
Peg Type Test Tube Racks, Polypropylene Drying Laboratory Type
Glass Thermometers, Green Filled General Purpose Laboratory Range
You May Also Need
Benchtop Touch Screen Multi-Parameter Meter for pH and Conductivity Testing
Multi Function Soil Meters with Stem Probes
Portable Single Parameters for pH, ORP, Conductivity and DO Testing
FEATURED PRODUCTS
BEST SELLING PRODUCTS
Petri Dishes, Polypropylene, Autoclavable & Reusable, High Quality
Glass Petri Dishes with Lid, Autoclavable, Borosilicate Glass (BORO 3.3)
Laboratory Beaker, Low Form, Graduated with Spout, Borosilicate Glass (BORO 3.3)
LATEST PRODUCTS
TOP RATED PRODUCTS
What Our Customers Say
Emma Roberts
11 months ago
We ordered a set of customised BORO 3.3 borosilicate glassware for our teaching labs, and LabChoice Australia exceeded every expectation. From the first consultation to final delivery, their team listened carefully, offered expert advice, and ensured every piece matched our specifications perfectly.
The clarity and precision of the glassware are exceptional, and the quick turnaround made setup effortless. It’s refreshing to work with an Australian supplier who genuinely understands laboratory needs and takes pride in quality craftsmanship. We’ll definitely be returning to LabChoice for future glassware requirements
Michael Grant
1 year ago
Our lab required high-precision BORO 3.3 glassware for analytical testing, and LabChoice Australia delivered outstanding results. The ordering process was simple, communication was clear, and every beaker and flask arrived perfectly calibrated and ready for use.
The quality of the glass is exceptional — resistant to heat, easy to clean, and consistently accurate in measurement. It’s reassuring to know there’s an Australian supplier that combines scientific precision with genuine customer care. I’d recommend LabChoice to any research team looking for dependable labware
Sarah Nguyen
1 year ago
We needed a set of customised borosilicate glassware for a specialised project, and LabChoice Australia delivered exactly what we envisioned. The team worked closely with us from design to production, ensuring every detail met our specifications. The craftsmanship is exceptional, and the turnaround time was impressive. It’s reassuring to know we can rely on them for unique, made-to-order pieces
Dr. Emily Hart – Senior Research Scientist
1 year ago
LabChoice Australia has completely changed the way we source our lab glassware. The quality is consistently top-notch, and every piece meets the precision we need for reliable results. Their team knows their stuff, answers our questions quickly, and always goes the extra mile to help — they’re more like partners than just a supplier.
Mark Stevens
1 year ago
We trust LabChoice Australia because they deliver every time. Their borosilicate glassware is durable, accurate, and perfect for the high-heat work we do. Everything arrives well-packed with clear specs, so there are never surprises. It’s reassuring to deal with a supplier who understands both compliance and the demands of a busy lab

































