E x p l o r e   M o r e :

Conductivity Meter Kit EC910 Benchtop with GLP Data Output, 0 to 200 mS/cm

AUD 1,025.00(Ex GST)

AUD 1,025.00(Ex GST)

  • Benchtop conductivity meter kit designed for routine EC, TDS, salinity and temperature testing workflows
  • Intuitive menu system and graphic prompts help reduce training time for daily laboratory users
  • GLP data management supports manual and automatic data logging with calibration records and time stamps
  • Flexible conductivity calibration supports standard solutions or user-defined standards for routine lab control
  • Broad electrode compatibility supports standard testing, high-range conductivity and high-purity water applications
  • Complete kit includes EC910 Conductivity Meter, 2301T-F Conductivity Electrode, 602 Flexible Electrode Holder, 84 µS/cm / 1413 µS/cm / 12.88 mS/cm Calibration Solutions, USB Cable, PC-Link 9500 Flash Drive, 9V Adapter and User Manual

View More

SKU: LC-86-AI5612 Category: Brand:
[request_quote_button]

Description

Conductivity Meter Kit EC910 Benchtop with GLP Data Output, 0 to 200 mS/cm, also known as a benchtop conductivity meter kit, is designed for laboratories that need guided EC, TDS, salinity and temperature measurement with structured data logging.

This kit is suitable for education, water-quality testing, quality control, research support and routine laboratory workflows where conductivity-related parameters need to be measured, stored and exported for review.

The EC910 uses an intuitive interface with plain-language menus and graphic screen prompts. This helps reduce training time and supports more consistent operation across shared laboratory environments.

The included 2301T-F conductivity electrode uses a firm platinum black sensor and supports high-accuracy conductivity measurement across the listed 0 to 200 mS/cm range. The meter also allows quick switching among conductivity, TDS and salinity, making it practical for routine water and solution analysis.

Flexible calibration supports 1–4 point automatic conductivity calibration using common standards including 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm. User-defined standards can also be used where the laboratory workflow requires custom calibration control.

GLP data management supports manual and automatic logging of up to 200 data sets with calibration data and time stamps. USB export to PC helps users manage measurement records for reporting, documentation and internal review.

Included with this Conductivity Meter Kit: EC910 Conductivity Meter, 602 Flexible Electrode Holder, 2301T-F Conductivity Electrode, 84 µS/cm Calibration Solution, 1413 µS/cm Calibration Solution, 12.88 mS/cm Calibration Solution, USB Cable, PC-Link 9500 Flash Drive, 9V Adapter and User Manual.

Users should follow the correct calibration, rinsing, electrode handling and data export procedure to support stable readings and electrode service life. Electrode selection should be confirmed for high-range conductivity or high-purity water testing.

Note before publishing: the supplied kit table lists EC910 pH/Conductivity Meter, while the product name is EC910 Benchtop Conductivity Meter Kit. Please confirm final product naming before upload.

LabChoice Australia supplies Conductivity Meter Kits for schools, universities, laboratories, water-quality users and QC teams requiring benchtop EC, TDS and salinity measurement with GLP data storage, USB export and flexible electrode compatibility.

Features

  • EC910 benchtop conductivity meter kit
  • Conductivity range: 0 to 200 mS/cm
  • Conductivity accuracy: ±1% F.S.
  • 2301T-F conductivity electrode included
  • 2301T-F electrode with ATC
  • Electrode cell constant: K = 1.0
  • Firm platinum black conductivity sensor
  • Measures conductivity
  • Measures TDS
  • Measures salinity
  • Supports temperature measurement through RCA temperature connector setup
  • Advanced plain-language menu interface
  • Graphic screen prompts
  • Multi-language support: English, German, Spanish and Chinese
  • Manual data logging
  • Automatic data logging
  • GLP-compliant data storage
  • Stores up to 200 data sets
  • Stores calibration data and time stamps
  • USB data export to PC
  • 1–4 point automatic conductivity calibration
  • Standard calibration solutions: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm
  • Supports user-defined calibration standards
  • One-tap switching among conductivity, TDS and salinity
  • Multiple salinity modes: general salinity, saltwater salinity and NaCl salinity
  • Standard BNC conductivity connector
  • Compatible with 2310T-F electrode for up to 2000 mS/cm applications
  • Compatible with DJS-0.1-F electrode for high-purity water applications
  • RCA temperature connector
  • NTC 30KΩ temperature connector compatibility
  • 602 flexible electrode holder included
  • 84 µS/cm calibration solution included, 50 mL
  • 1413 µS/cm calibration solution included, 50 mL
  • 12.88 mS/cm calibration solution included, 50 mL
  • USB cable included
  • PC-Link 9500 flash drive included
  • 9V adapter included
  • User manual included
  • Calibration routine, electrode selection, salinity mode, PC export requirements and sample conductivity range should be confirmed before use

Warranty

The instrument is covered for defects in material and workmanship for three years, while the probe is covered for six months from delivery, subject to the manufacturer’s warranty terms.

The limited warranty does not cover issues caused by accidental damage, improper use, normal wear and tear, transport, storage, failure to follow product instructions, unauthorised maintenance, unauthorised modification, unauthorised repair, incompatible use with other products or materials, abuse, accidents or external causes beyond reasonable control.

Parameter Settings Menu

Parameter Menu Options Factory Default
2.0 Conductivity / TDS – –
2.1 Cell Constant 10 / 1.0 / 0.1 1.0
2.2 CAL Solution Selection Standard / CN / User Standard
2.3 Last Calibration Data View –
2.4 Reference Temperature 15–30 °C 25 °C
2.5 Temp Compensation Factor 0.00–10.00% 2.0%
2.6 TDS Factor 0.40–1.00 0.71
2.7 Restore Factory Default Yes / No No
3.0 Configuration
3.1 Reading with HOLD On / Off –
3.2 Auto Timing Data Log Manual / Automatically Manual
3.3 Temperature Unit °C / °F –
3.4 Delete Saved Data Yes / No No
3.5 Language Selection English / Deutsch / Español / Chinese –
3.6 Date Format Y-M-D –
3.7 Time Format 24-hour / 12-hour –
3.8 Date Setting YYYY-MM-DD –
3.9 Time Setting HH:MM:SS –

What’s in the Kit?

Item Quantity
EC910 pH/Conductivity Meter 1
602 Flexible Electrode Holder 1
2301T-F Conductivity Electrode (ATC, K=1.0) 1
Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3
USB Cable 1
PC-Link 9500 Flash Drive 1
9V Adapter 1
User Manual 1