E x p l o r e   M o r e :

Portable Conductivity/TDS/Salinity/Resistivity Meter Kit EC8500 with GLP Data Logger, 0 to 200 mS/cm

AUD 785.00(Ex GST)

AUD 785.00(Ex GST)

  • Premium portable conductivity meter kit designed for lab-grade EC measurement in field and laboratory workflows
  • Suitable for water treatment, drinking water, aquariums, aquaculture, hydroponics, pools, spas and environmental monitoring
  • Supports conductivity, TDS, salinity, resistivity and temperature testing in one rugged handheld meter format
  • GLP data management helps users store readings, review calibration information and support reporting workflows
  • USB data output supports measurement transfer for further analysis and documentation
  • Complete kit includes EC8500 Meter, 2301T-S Conductivity Electrode, 12.88 mS, 1413 µS and 84 µS Calibration Solutions, USB Cable, Software Flash Drive, User Manual, Carrying Case and Screwdriver

View More

SKU: LC-86-AI5522 Category: Brand:
[request_quote_button]

Description

Portable Conductivity/TDS/Salinity/Resistivity Meter Kit EC8500 with GLP Data Logger, 0 to 200 mS/cm, also known as a premium portable conductivity meter kit, is designed for lab-grade conductivity measurement in field, onsite and routine laboratory environments. This meter is suitable for water treatment, drinking water checks, aquariums, aquaculture, hydroponics, greenhouse applications, pools, spas, education, environmental monitoring and beverage-making workflows where portable EC-based water testing is required.

The EC8500 supports conductivity, TDS, salinity, resistivity and temperature measurement in one handheld meter format. One-tap switching helps users move between common water-quality parameters without needing separate instruments for each routine measurement.

The supplied 2301T-S conductivity electrode uses a platinum black conductivity cell with K = 1 cell constant. It supports wide-range conductivity measurement up to 200 mS/cm / 200,000 µS/cm and includes a built-in temperature sensor for temperature-compensated measurement workflows.

GLP data management supports manual or automatic data logging, with storage for up to 500 measurement sets. USB data output allows users to transfer stored measurements for further analysis, reporting and record keeping. The meter supports quick 1–3 point automatic conductivity calibration and recognises 84 µS, 1413 µS, 12.88 mS and 111.8 mS conductivity standards. Last calibration date check and calibration reminder functions help support routine calibration control.

Users can customise measurement settings including temperature unit, conductivity cell constant, reference temperature, temperature compensation coefficient and TDS conversion factor from 0.40 to 1.00. The large backlit LCD shows conductivity-related readings, temperature, time, stability status, calibration indicators and data storage status. The IP57 water-resistant structure and protective rubber sleeve support field use in demanding testing environments.

Included with this Portable Conductivity Meter Kit: User Manual, Carrying Case, USB Cable, Software Flash Drive, Screwdriver, EC8500 Meter, 12.88 mS Calibration Solution, 1413 µS Calibration Solution, 84 µS Calibration Solution and 2301T-S Conductivity Electrode.

Users should follow correct calibration, rinsing, electrode cleaning and storage procedures to support stable readings and electrode service life. Conductivity cells should be kept clean, especially after testing samples that may leave residue or deposits.

LabChoice Australia supplies portable conductivity/TDS/salinity meter kits for schools, universities, laboratories, water-treatment teams, hydroponic users, aquaculture users, environmental monitoring teams and routine onsite water-quality testing workflows.

Features

  • EC8500 portable conductivity meter kit
  • Premium Series conductivity meter
  • Measures conductivity, TDS, salinity, resistivity and temperature
  • Conductivity measuring range listed for 2301T-S electrode: 0 to 200 mS/cm / 200,000 µS/cm
  • Conductivity accuracy listed for 2301T-S electrode: ±1% F.S.
  • One-tap switching between measurement parameters
  • GLP data management
  • 500 sets of data storage
  • Manual data logging
  • Automatic data logging
  • USB data output
  • Quick 1–3 point automatic conductivity calibration
  • Recognises conductivity standards: 84 µS, 1413 µS, 12.88 mS and 111.8 mS
  • Last calibration date check available
  • Calibration reminder setting available
  • Auto-lock function
  • Auto power-off function
  • Temperature unit setting
  • Customisable conductivity cell constant
  • Customisable reference temperature
  • Customisable temperature compensation coefficient
  • TDS conversion factor setting: 0.40 to 1.00
  • Large backlit LCD display
  • Stability icon for stable readings
  • Finished calibration icons
  • Simultaneous temperature display
  • Time display
  • Data storage indicator
  • IP57 water-resistant structure
  • Rubber sleeve for impact protection and firm grip
  • Suitable for field use and benchtop-style operation
  • Includes 2301T-S platinum black conductivity electrode
  • 2301T-S electrode cell constant: K = 1
  • Built-in temperature sensor in electrode
  • PVC electrode body
  • Includes EC8500 meter
  • Includes USB cable
  • Includes software flash drive
  • Includes screwdriver
  • Includes 12.88 mS calibration solution
  • Includes 1413 µS calibration solution
  • Includes 84 µS calibration solution
  • Includes user manual
  • Includes carrying case
  • Calibration routine, TDS factor, conductivity cell constant, software compatibility, data export workflow and sample suitability should be confirmed before use
Technical Specifications
Cond. Measuring Range Conductivity:0 to 1999 mS/cm, divided into six ranges, automatically switches measuring range.
(0 to 19.99) μS/cm;
(0 to 19.99) μS/cm;
(200 to 1999) μS/cm;
(2.00 to 19.99) mS/cm;
(20.0 to 199.9) mS/cm;
(200 to 1999) mS/cm;
TDS: (0 to 100) g/L;
Salinity: (0 to 100) ppt
Resolution 0.01/0.1/1μS/cm  0.01/0.1 mS/cm
Accuracy ±1.0% F.S.±1 digit
Temperature Compensation Range  (0 to 50)˚C (Auto. or Manual)
Cell constant 0.1/1/10 cm-1
Temp. Measuring Range 0 to 100℃
Resolution 0.1℃
Accuracy ±0.5℃±1 digit
.

Other Specifications

Data Storage 500 sets
Storage Content Numbering, measuring value and temperature value, data and time
Power 3* AA alkaline batteries
Dimension & Weight Meter: (88*170*33)mm / 313g
Case: (360*270*76)mm / 1.6kg
Connector RCA for temperature, 8-pin for conductivity
 What’s in the box? EC8500 meter, 2301T-S conductivity/temp. electrode, electrode clip, software flash drive, USB cable, 50ml of conductivity standards (1413µS, 12.88mS), screwdriver (for battery replacement), instruction manual, carrying case