Conductivity Meter Kit EC700 Benchtop with 2301T-F Electrode, 0 to 200.00 mS/cm

AUD 870.00(Ex GST)

AUD 870.00(Ex GST)

  • Benchtop conductivity meter kit designed for routine laboratory, education and general water-solution testing workflows
  • Measures conductivity and temperature together using the included 2301T-F conductivity / temperature electrode
  • Automatic calibration and self-diagnosis help support consistent daily conductivity measurement
  • ATC support is useful where sample temperature changes during routine water testing
  • Built-in data storage and Max / Min mode help users review readings during QC and process checks
  • Complete starter kit includes EC700 Benchtop Conductivity Meter, 2301T-F Conductivity / Temperature Electrode, 84 µS/cm, 1413 µS/cm and 12.88 mS/cm Calibration Solutions, Electrode Holder, Power Adapter, User Manual and Quick Start Guide

View More

SKU: LC-86-AI502 Category: Brand:
[request_quote_button]

Description

Conductivity Meter Kit EC700 Benchtop with 2301T-F Electrode, 0 to 200.00 mS/cm, also known as a benchtop conductivity meter kit, is designed for routine conductivity and temperature measurement in compatible general water solution applications.

This kit is suitable for education, water testing, laboratory bench work, basic QC checks and general solution measurement where a stable benchtop meter format is preferred over a handheld tester.

The included 2301T-F conductivity / temperature electrode uses a firm platinum-black cell to support fast and stable conductivity measurement across the listed 0 to 200.00 mS/cm range. The meter supports conductivity and temperature measurement together, helping users review sample conditions during routine testing.

The 1–4 point automatic calibration function recognises common conductivity standards including 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm. Calibration guide and self-diagnosis functions help users manage routine calibration and check measurement readiness.

Automatic temperature compensation from 0–50°C supports more consistent readings when sample temperature varies. The meter also includes adjustable settings for cell constant, reference temperature, temperature compensation coefficient, TDS factor, temperature unit, stored data clearing and factory reset.

The IP54 splash-proof and dust-proof design supports routine bench use, while the included electrode holder keeps the probe stable during testing. Built-in memory stores up to 50 measurement sets, and Max / Min mode allows users to quickly review highest and lowest readings during analysis.

Included with this Conductivity Meter Kit: EC700 Benchtop Conductivity Meter, 2301T-F Conductivity / Temperature Electrode, 1413 µS/cm Calibration Solution, 12.88 mS/cm Calibration Solution, 84 µS/cm Calibration Solution, Electrode Holder, Power Adapter, User Manual and Quick Start Guide.

Users should follow the correct calibration, rinsing, electrode handling and storage procedure to support stable readings and electrode service life. Cell constant selection, calibration solution choice, TDS factor and sample range should be confirmed before regular testing.

LabChoice Australia supplies Conductivity Meter Kits for schools, universities, laboratories, water-quality users and QC teams requiring benchtop conductivity measurement with ATC, calibration support, data storage and stable electrode positioning.

Features

  • EC700 benchtop conductivity meter kit
  • Conductivity range: 0 to 200.00 mS/cm
  • Conductivity accuracy: ±1% F.S.
  • 2301T-F conductivity / temperature electrode included
  • Firm platinum-black conductivity cell
  • Simultaneous conductivity and temperature measurement
  • Automatic temperature compensation: 0–50°C
  • 1–4 point automatic calibration
  • Recognised conductivity standards: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm
  • Calibration guide function
  • Self-diagnosis function
  • IP54 splash-proof and dust-proof design
  • Stores and recalls up to 50 sets of measurements
  • Max / Min measuring mode
  • Minimalist electrode holder included
  • Parameter setting P1: electrode cell constant selection, K = 0.1 / 1.0 / 10
  • Parameter setting P2: reference temperature selection, 15–30°C adjustable
  • Parameter setting P3: temperature compensation coefficient, 0.00–9.99% adjustable
  • Parameter setting P4: TDS factor, 0.40–1.00 adjustable
  • Parameter setting P5: temperature unit selection, °C / °F
  • Parameter setting P6: clear stored data
  • Parameter setting P7: restore factory default
  • Includes EC700 Benchtop Conductivity Meter
  • Includes 2301T-F Conductivity / Temperature Electrode
  • Includes 1413 µS/cm Calibration Solution, 50 mL
  • Includes 12.88 mS/cm Calibration Solution, 50 mL
  • Includes 84 µS/cm Calibration Solution, 50 mL
  • Includes Electrode Holder
  • Includes Power Adapter
  • Includes User Manual
  • Includes Quick Start Guide
  • Calibration routine, cell constant selection, TDS factor, temperature compensation coefficient and sample compatibility should be confirmed before use

Warranty

The instrument is covered for defects in material and workmanship for two years, while the probe is covered for six months from delivery, subject to the manufacturer’s warranty terms.

The limited warranty does not cover issues caused by accidental damage, improper use, normal wear and tear, transport, storage, failure to follow product instructions, unauthorised maintenance, unauthorised modification, unauthorised repair, incompatible use with other products or materials, abuse, accidents or external causes beyond reasonable control.

Model PH700
Conductivity Measuring Range Conductivity: 0~200.0 mS/cm_include (0 to 199.9) μS/cm; (200 to 1999) μS/cm;
(2.00 to 19.99) mS/cm_(20.0 to 199.9) mS/cm
Conductivity Resolution 0.1/1μS/cm_0.01/0.1 mS/cm
Conductivity Accuracy ±1.0% F.S.
Conductivity Temperature Compensation 0 to 50°C (32 to 212°F) Auto or Manual
Conductivity Electrode Constant 0.1 / 1 / 10 cm-1
Conductivity Reference Temperature 25°C
Conductivity Temperature Coefficient 0.00 to 9.99%/°C, default: 2.00%/°C
Conductivity Calibration 1 to 4 points auto calibration
Temperature Measuring Range 0 to 100°C (32 to 212°F)
Temperature Resolution 0.1°C; 0.1/1?F
Temperature Accuracy ±0.5°C
Others Data Storage 50 sets
Others Storage Content Numbering, measurements, unit, temperature, and status of temperature compensation
Others Power Supply Input: 120V AC 60Hz; Output: DC9V/300mA, 2.7VA
Others IP Rating IP54 splash-proof and dust-proof
Others Dimensions and Weight (9.5*9.3*4) inches / 2.2 pounds; With case: (12*10*5) inches / 3 pounds