E x p l o r e   M o r e :

pH/Conductivity Meter Kit PC950 with TestBench, 0.00 to 14.00 pH, 0 to 200 mS/cm

AUD 1,930.00(Ex GST)

AUD 1,930.00(Ex GST)

  • Dual-channel benchtop meter kit designed for simultaneous pH / mV and conductivity-related testing workflows
  • Apera TestBench helps streamline calibration and measurement with electrode holder, magnetic stirrer and buffer organisers
  • Suitable for laboratories that need pH, ORP, conductivity, TDS, salinity, resistivity and temperature testing from one bench instrument
  • Plain-language menus, graphic prompts and multi-language support help reduce training time for routine users
  • GLP data management supports manual and automatic logging with calibration records, time stamps and USB export
  • Complete kit includes PC950 pH / Conductivity Meter, 606 Test-Bench with Flexible Electrode Holder, LabSen® 211 Glass pH Combination Electrode, MP500 Temperature Electrode, 2401T-F Conductivity Electrode, pH 4.00 / 7.00 / 10.01 Buffers, 84 µS / 1413 µS / 12.88 mS Conductivity Calibration Solutions, Stirrer Power Cable, USB Cable, PC-Link Flash Drive, 9V Adapter, Calibration Vials, L200 Stir Beads and User Manual

View More

SKU: LC-86-AI5624 Category: Brand:
[request_quote_button]

Description

pH/Conductivity Meter Kit PC950 with TestBench, 0.00 to 14.00 pH, 0 to 200 mS/cm, also known as a benchtop pH and conductivity meter kit with integrated workstation, is designed for laboratories that need simultaneous pH / mV and conductivity-related measurement from one organised bench setup.

This kit is suitable for education, research support, quality control, water testing and routine laboratory workflows where pH, ORP, conductivity, TDS, salinity, resistivity and temperature readings need to be measured, logged and reviewed.

The included Apera TestBench provides an integrated workstation with flexible electrode holder, intelligent magnetic stirrer and buffer organisers. This helps users manage calibration buffers, conductivity standards, electrode positioning and sample mixing more efficiently during daily bench testing.

The PC950 uses an advanced interface with plain-language menus and graphic screen prompts. This helps reduce operator training time and supports more consistent use in shared laboratory environments. Multi-language support includes English, German, Spanish and Chinese.

The pH channel includes a LabSen® 211 glass pH combination electrode and MP500 temperature electrode. The LabSen® 211 electrode features a low-impedance glass membrane, long-life reference system and TRIS buffer compatibility, while the MP500 supports 0–100°C automatic temperature compensation.

The conductivity channel includes a 2401T-F conductivity electrode with ATC and K = 1.0 cell constant. The glass-body platinum black sensor supports conductivity measurement across the listed 0 to 200 mS/cm range, with quick switching among conductivity, TDS and salinity.

The meter supports 1–3 point pH calibration and 1–4 point conductivity calibration using standard or user-defined calibration options. Automatic electrode slope display and calibration self-diagnosis help users review calibration quality and electrode condition before routine measurement.

GLP data management supports manual and automatic logging of up to 200 data sets, including calibration records and time stamps. USB export to PC helps users manage measurement records for reporting, review and laboratory documentation.

Included with this pH / Conductivity Meter Kit: PC950 pH / Conductivity Meter, 606 Test-Bench with Flexible Electrode Holder, LabSen® 211 Glass pH Combination Electrode, MP500 Temperature Electrode, 2401T-F Conductivity Electrode, pH 4.00 Buffer, pH 7.00 Buffer, pH 10.01 Buffer, 84 µS Conductivity Calibration Solution, 1413 µS Conductivity Calibration Solution, 12.88 mS Conductivity Calibration Solution, Stirrer Power Cable, USB Cable, PC-Link Flash Drive, 9V Adapter, 6 Calibration Vials, 6 L200 Stir Beads and User Manual.

Users should follow correct calibration, rinsing, electrode storage, stirring setup and data export procedures to support reading stability, electrode service life and reliable record keeping. Electrode selection should be confirmed for specialised pH samples, high-range conductivity or high-purity water testing.

LabChoice Australia supplies pH / Conductivity Meter Kits for schools, universities, laboratories, QC teams and water-quality users requiring dual-channel benchtop measurement with TestBench workflow support, GLP data storage, USB export and flexible electrode compatibility.

Features

  • PC950 benchtop pH / conductivity meter kit
  • Dual-channel simultaneous measurement
  • pH measuring range: 0.00 to 14.00 pH
  • Conductivity range: 0 to 200 mS/cm
  • Conductivity accuracy: ±1% F.S.
  • Measures pH
  • Measures mV / ORP
  • Measures conductivity / EC
  • Measures TDS
  • Measures salinity
  • Measures resistivity
  • Measures temperature
  • Apera 606 Test-Bench included
  • Integrated workstation format
  • Flexible electrode holder included
  • Intelligent magnetic stirrer included
  • Buffer organisers included
  • Advanced plain-language menu interface
  • Graphic screen prompts
  • Multi-language support: English, German, Spanish and Chinese
  • Manual data logging
  • Automatic data logging
  • GLP-compliant data storage
  • Stores up to 200 data sets
  • Stores calibration data and time stamps
  • USB data export to PC
  • LabSen® 211 glass pH combination electrode included
  • Low-impedance glass membrane
  • Long-life reference system
  • Compatible with TRIS buffers
  • MP500 temperature electrode included
  • 0–100°C ATC support via MP500 temperature probe
  • 1–3 point automatic pH calibration
  • pH standard buffer recognition: 1.68, 4.00, 7.00, 10.01 and 12.45
  • Supports user-defined pH calibration standards
  • Automatic electrode slope display
  • Calibration self-diagnosis
  • Standard BNC pH connector
  • RCA temperature connector
  • NTC 30KΩ temperature connector compatibility
  • Compatible with Swiss LabSen electrodes for specialised sample applications
  • 2401T-F conductivity electrode included
  • 2401T-F conductivity electrode with ATC
  • Conductivity electrode cell constant: K = 1.0
  • Glass-body platinum black conductivity sensor
  • 1–4 point automatic conductivity calibration
  • Conductivity standard recognition: 84 µS/cm, 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm
  • Supports user-defined conductivity calibration standards
  • One-tap switching among conductivity, TDS and salinity
  • Standard BNC conductivity connector
  • Compatible with 2310T-F electrode for up to 2000 mS/cm applications
  • Compatible with DJS-0.1-F electrode for high-purity water applications
  • pH 4.00 buffer included, 50 mL
  • pH 7.00 buffer included, 50 mL
  • pH 10.01 buffer included, 50 mL
  • 84 µS conductivity calibration solution included, 50 mL
  • 1413 µS conductivity calibration solution included, 50 mL
  • 12.88 mS conductivity calibration solution included, 50 mL
  • Stirrer power cable included
  • USB cable included
  • PC-Link flash drive included
  • 9V adapter included
  • 6 calibration vials included
  • 6 L200 stir beads included
  • User manual included
  • Calibration routine, TestBench setup, magnetic stirring speed, electrode selection, ATC setup and PC export requirements should be confirmed before use

Warranty

The instrument is covered for defects in material and workmanship for three years, while the probe is covered for six months from delivery, subject to the manufacturer’s warranty terms.

The limited warranty does not cover issues caused by accidental damage, improper use, normal wear and tear, transport, storage, failure to follow product instructions, unauthorised maintenance, unauthorised modification, unauthorised repair, incompatible use with other products or materials, abuse, accidents or external causes beyond reasonable control.

 

Parameter Settings Menu

Parameter Menu Options Factory Default
1.0 pH
1.1 pH Buffer Selection CH / USA / NIST / User USA
1.2 Resolution 0.01 / 0.1 0.01
1.3 Last Calibration Data View –
1.4 Restore Factory Default Yes / No No
2.0 Conductivity / TDS
2.1 Cell Constant 10 / 1.0 / 0.1 1.0
2.2 CAL Solution Selection Standard / CN / User Standard
2.3 Last Calibration Data View –
2.4 Reference Temperature 15–30 °C 25 °C
2.5 Temp Compensation Factor 0.00–10.00% 2.0%
2.6 TDS Factor 0.40–1.00 0.71
2.7 Restore Factory Default Yes / No No
3.0 Configuration
3.1 Reading with HOLD On / Off –
3.2 Auto Timing Data Log Manual / Automatically Manual
3.3 Temperature Unit °C / °F –
3.4 Delete Saved Data Yes / No No
3.5 Language Selection English / Deutsch / Español / Chinese English
3.6 Date Format Y-M-D –
3.7 Time Format 24-hour / 12-hour –
3.8 Date Setting YYYY-MM-DD –
3.9 Time Setting HH:MM:SS –

What’s in the Kit?

Item Quantity
PC950 pH/Conductivity Meter 1
606 Test-Bench (with flexible electrode holder) 1
LabSen 211 Glass pH Combination Electrode 1
MP500 Temperature Electrode 1
2401T-F Conductivity Electrode (ATC, K=1.0) 1
pH Standard Buffers (4.00 / 7.00 / 10.01 pH, 50mL each) 3
Conductivity Calibration Solutions (84 µS / 1413 µS / 12.88 mS, 50mL each) 3
Stirrer Power Cable 1
USB Cable 1
PC-Link Flash Drive 1
9V Adapter 1
Calibration Vials 6
L200 Stir Beads 6
User Manual 1

Specifications

Datasheets & Manuals

Document :
Product Information Sheet(Pdf)

[porto_related_products_slider]