E x p l o r e   M o r e :

Portable pH Meter Kit PH8500-SA with LabSen 843 Electrode for Strong Alkaline and High Salinity Solutions, -2.00 to 16.00 pH

AUD 1,050.00(Ex GST)

AUD 1,050.00(Ex GST)

  • Portable pH meter kit designed for strong alkaline and high salinity solution measurement workflows
  • Suitable for laboratories, QC teams and field users working with compatible alkaline or saline samples
  • LabSen® 843 electrode supports pH measurement in high-pH and high-salt samples where alkaline error can affect readings
  • GLP data management supports measurement storage, calibration records and USB data output for reporting workflows
  • Rugged handheld design supports field, laboratory and benchtop-style operation
  • Complete kit includes PH8500 Meter, LabSen® 843 pH Electrode, MP500 Temperature Electrode, Reference Soaking Solution, pH 4.00 / 7.00 / 12.45 Calibration Solutions, USB Cable, Software Flash Drive, User Manual, Carrying Case and Screwdriver

View More

SKU: LC-86-AI5523 Category: Brand:
[request_quote_button]

Description

Portable pH Meter Kit PH8500-SA with LabSen 843 Electrode for Strong Alkaline and High Salinity Solutions, -2.00 to 16.00 pH, also known as a strong alkaline pH meter kit, is designed for professional pH measurement in compatible high-pH and high-salinity sample workflows. This kit is suitable for strong alkaline solutions, high salinity solutions and general water solutions where the correct electrode selection is required. It is useful for laboratories, industrial QC teams, water testing users, research facilities and field measurement workflows.

The supplied LabSen® 843 pH electrode is designed for strong alkaline and high salinity samples. Its HA glass membrane is made for alkaline solution measurement, especially in the 10–14 pH region where sodium-ion interference can cause alkaline measurement error.

The electrode uses a blue gel inner solution and silver-ion-trap reference system to support stable measurement in compatible alkaline and saline samples. Supplied information states that service life is longer than conventional electrodes when used for these sample types under suitable conditions. The kit also includes an MP500 temperature electrode for temperature measurement with the PH8500 meter. The PH8500 meter supports self-diagnosis, calibration reminders, calibration date checking, clock display and easy parameter setting for controlled routine use.

GLP standard data management supports up to 500 stored data sets, with manual or automatic storage. USB data output and the supplied software flash drive support data transfer for review, analysis and reporting. The large white backlit LCD, IP57 waterproof rating, soft silicone case and foldable stand make the meter practical for field use, laboratory benches and benchtop-style operation.

Included with this Portable pH Meter Kit: User Manual, Carrying Case, USB Cable, Software Flash Drive, Screwdriver, PH8500 Meter, pH 12.45 Calibration Solution, pH 7.00 Calibration Solution, pH 4.00 Calibration Solution, Reference Soaking Solution, LabSen® 843 pH Electrode and MP500 Temperature Electrode.

Users should follow correct calibration, rinsing, soaking and electrode storage procedures to support stable readings and electrode service life. For strong alkaline and high salinity samples, sample compatibility, temperature condition and electrode cleaning should be confirmed before routine testing.

LabChoice Australia supplies strong alkaline pH meter kits for laboratories, universities, industrial QC users, water testing teams, research facilities and controlled workflows requiring pH measurement in compatible alkaline or high salinity samples.

Features

  • PH8500-SA portable pH meter kit
  • pH measuring range: -2.00 to 16.00 pH
  • Designed for strong alkaline solutions
  • Designed for high salinity solutions
  • Equipped with Swiss LabSen® 843 refillable pH electrode
  • MP500 temperature electrode included
  • HA glass membrane for alkaline and high salinity samples
  • Blue gel inner solution
  • Silver-ion-trap reference system
  • Reference soaking solution included
  • Supplied information states the HA membrane is made for 10–14 pH strong alkaline solutions
  • Supplied information states the HA membrane helps minimise alkaline error caused by sodium ions
  • Supplied information states service life is 5 times longer than conventional electrodes when testing these samples
  • Self-diagnosis for out-of-range values and electrode invalidation
  • Calibration reminders
  • Calibration date checking
  • Clock display
  • Easy parameter setting
  • GLP standard data management
  • 500 data sets of storage
  • Manual data storage
  • Automatic data storage
  • USB data output
  • Large white backlit LCD display
  • Soft silicone case for firm and comfortable grip
  • IP57 waterproof rating
  • Powered by AA batteries
  • Foldable stand for benchtop-style use
  • Includes PH8500 meter
  • Includes LabSen® 843 pH Electrode
  • Includes MP500 Temp. Electrode
  • Includes reference soaking solution
  • Includes pH 12.45 calibration solution
  • Includes pH 7.00 calibration solution
  • Includes pH 4.00 calibration solution
  • Includes USB cable
  • Includes software flash drive
  • Includes user manual
  • Includes carrying case
  • Includes screwdriver
  • Calibration routine, alkaline sample compatibility, salinity level, electrode rinsing, soaking method and storage procedure should be confirmed before use
Technical Specs
PH Range -2.00 to 16.00 pH
Resolution 0.01/0.1 pH
Accuracy ±0.01 pH ±1 digit
Temperature Compensation 0 to 100°C (Auto or Manual)
mV Range -1999 mV – 0 – 1999 mV
Resolution – 200 mV – 0 – 200 mV: 0.1 mV; Remaining: 1 mV
Accuracy ±0.1% F.S ±1 digit
Temp. Range -5 to 100°C (23 to 212°F)
Resolution 0.1°C
Accuracy ±0.5°C ±1 digit
.
Other Specs
Data Storage 500 groups
Storage Content Numbering, date, time, measurement, unit, temperature
Output USB
Power AA Batteries * 3 / DC5V (USB port)
IP Ranking IP57 dust-proof and waterproof
Dimensions & Weight Meter: (88_170_33 ) mm/ 313g With case_(360_270_76) mm/ 1.6kg
.
pH Electrode Specs (LabSen 843)
Housing Material Lead-free glass
Temperature sensor 30KΩ NTC
Junction Ceramic
Reference Electrode Silver ion trap
Electrolyte 3M KCL
Shape of glass membrane hemisphere
Range 2 to 14 pH
Temperature Range 0 to 100°C (32 to 212°F)
Connector BNC and RCA