E x p l o r e   M o r e :

Portable pH Meter Kit PH8500-HF with LabSen 833 Electrode for Strong Acid and HF Solutions, -2.00 to 16.00 pH

AUD 1,050.00(Ex GST)

AUD 1,050.00(Ex GST)

  • Portable pH meter kit designed for specialised strong acid and hydrofluoric acid solution measurement workflows
  • Suitable for trained laboratory users working with compatible corrosive samples and storage battery solutions
  • LabSen® 833 HF-resistant pH electrode supports controlled measurement in selected HF-containing solutions
  • GLP data management supports measurement storage, calibration records and USB data output for reporting workflows
  • Separate MP500 temperature electrode supports temperature measurement with compatible PH8500 meter operation
  • Complete kit includes PH8500 Meter, LabSen® 833 pH Electrode, MP500 Temperature Electrode, Reference Soaking Solution, pH 1.68 / 7.00 / 10.01 Calibration Solutions, USB Cable, Software Flash Drive, User Manual, Carrying Case and Screwdriver

View More

SKU: LC-86-AI5525 Category: Brand:
[request_quote_button]

Description

Portable pH Meter Kit PH8500-HF with LabSen 833 Electrode for Strong Acid and HF Solutions, -2.00 to 16.00 pH, also known as an HF-compatible pH meter kit, is designed for specialised pH measurement in compatible strong acid and hydrofluoric acid solution workflows. This kit is intended for trained laboratory users working with corrosive samples, strong acid solutions, selected HF-containing solutions and storage battery solution applications. Hydrofluoric acid requires strict safety controls, so users should follow approved laboratory procedures before use.

The supplied LabSen® 833 pH electrode is designed for measurement in selected strong acid and hydrofluoric acid solutions. Supplied information states that HF testing should be limited to concentrations below 0.1 mol/L or 0.2 wt%, with measurement time below 1 minute.

The electrode uses an HF glass membrane, blue gel inner solution and silver-ion-trap reference system. These design features support measurement in compatible acid sample workflows where ordinary pH electrodes may not be suitable. The kit also includes an MP500 temperature electrode for temperature measurement with the PH8500 meter. The PH8500 meter provides self-diagnosis, calibration reminders, calibration date checking, clock display and easy parameter setting for controlled routine operation.

GLP standard data management supports up to 500 stored data sets, with manual or automatic storage. USB data output and the supplied software flash drive support data transfer for review, analysis and reporting. The large white backlit LCD, IP57 waterproof rating, soft silicone case and foldable stand make the meter suitable for handheld use and benchtop-style laboratory operation.

Included with this Portable pH Meter Kit: User Manual, Carrying Case, USB Cable, Software Flash Drive, Screwdriver, PH8500 Meter, pH 10.01 Calibration Solution, pH 7.00 Calibration Solution, pH 1.68 Calibration Solution, Reference Soaking Solution, LabSen® 833 pH Electrode and MP500 Temperature Electrode.

Users should follow correct calibration, rinsing, soaking and electrode storage procedures to support stable readings and electrode service life. For HF and strong acid samples, concentration limit, contact time, chemical compatibility, PPE and disposal procedure must be confirmed before routine testing.

LabChoice Australia supplies specialised pH meter kits for laboratories, research facilities, industrial QC users and controlled workflows requiring pH measurement in compatible strong acid or HF-containing samples.

Features

  • PH8500-HF portable pH meter kit
  • pH measuring range: -2.00 to 16.00 pH
  • Designed for solutions containing strong acid or hydrofluoric acid
  • Suitable for storage battery solution workflows, as listed in supplied information
  • Equipped with LabSen® 833 pH electrode
  • MP500 temperature electrode included
  • HF glass membrane
  • Blue gel inner solution
  • Silver-ion-trap reference system
  • Reference soaking solution included
  • Supplied information states HF solution measurement up to 1000 times under specified conditions
  • Supplied information states measurement time should be less than 1 minute for HF solution testing
  • Supplied information states HF concentration should be less than 0.1 mol/L or 0.2 wt%
  • Self-diagnosis for out-of-range values and electrode invalidation
  • Calibration reminders
  • Calibration date checking
  • Clock display
  • Easy parameter setting
  • GLP standard data management
  • 500 data sets of storage
  • Manual data storage
  • Automatic data storage
  • USB data output
  • Large white backlit LCD display
  • Soft silicone case for firm and comfortable grip
  • IP57 waterproof rating
  • Powered by AA batteries
  • Foldable stand for benchtop-style use
  • Includes PH8500 meter
  • Includes LabSen® 833 pH Electrode
  • Includes MP500 Temp. Electrode
  • Includes reference soaking solution
  • Includes pH 10.01 calibration solution
  • Includes pH 7.00 calibration solution
  • Includes pH 1.68 calibration solution
  • Includes USB cable
  • Includes software flash drive
  • Includes user manual
  • Includes carrying case
  • Includes screwdriver
  • HF concentration limit, exposure time, calibration routine, electrode rinsing, soaking method, PPE and chemical safety procedure should be confirmed before use
Technical Specs
pH Range -2.00 to 16.00 pH
Resolution 0.01/0.1 pH
Accuracy ±0.01 pH ±1 digit
Temperature Compensation 0 to 100°C (Auto or Manual)
mV Range -1999 mV – 0 – 1999 mV
Resolution – 200 mV – 0 – 200 mV: 0.1 mV; Remaining: 1 mV
Accuracy ±0.1% F.S ±1 digit
Temp. Range -5 to 100°C (23 to 212°F)
Resolution 0.1°C
Accuracy ±0.5°C ±1 digit
.
Other Specs
Data Storage 500 groups
Storage Content Numbering, date, time, measurement, unit, temperature
Output USB
Power AA Batteries * 3 / DC5V (USB port)
IP Ranking IP57 dust-proof and waterproof
Dimensions& Weight Meter: (88_170_33 ) mm/ 313g With case_(360_270_76) mm/ 1.6kg
.
pH Electrode Specs (LabSen 833)
Housing Material Lead-free glass
Temperature sensor 30KΩ NTC
Junction Ceramic
Reference Electrode Silver ion trap
Electrolyte 3M KCL
Shape of glass membrane hemisphere
Range 0 to 11 pH
Temperature Range 0 to 100°C (32 to 212°F)
Connector BNC and RCA

Datasheets & Manuals

Document :
Product Information Sheet(Pdf)