E x p l o r e   M o r e :

pH/Temp Electrode for Strong Acid and Hydrofluoric Acid Liquids, Non-Refillable, 0–12 pH

AUD 360.00(Ex GST)

AUD 360.00(Ex GST)

  • Non-refillable pH / temperature electrode for strong acid and hydrofluoric acid-containing liquid workflows
  • Designed for pH measurement in liquids containing strong acids or HF under specified conditions
  • HF-type membrane helps resist hydrofluoric corrosion and minimise acidic error
  • Listed for up to 1000 HF measurements when measurement time is less than 1 minute and HF concentration is below 0.1 mol/L or 2000 ppm
  • Open junction and polymer electrolyte support full sample contact while reducing junction clogging
  • Built-in temperature sensor supports automatic temperature compensation on compatible meters

View More

SKU: LC-86-ALabSen835 Category: Brand:
[request_quote_button]

Description

Non-Refillable pH/Temp Electrode for Strong Acid and Hydrofluoric Acid Liquids, 0–12 pH, also known as an acid-resistant pH / temperature electrode, is designed for users who need specialised pH measurement in aggressive acidic liquid samples.

This electrode is suitable for laboratories, research facilities, water-quality teams, process testing areas and quality-control workflows where strong acid or HF-containing samples require careful electrode selection and controlled measurement practice.

The HF-type membrane supports use in acidic applications where hydrofluoric corrosion and acidic error may affect standard electrode performance. The open junction and polymer electrolyte format help maintain contact with the sample while reducing clogging risk during compatible liquid testing.

The Silver Ion Trap reference system supports stable reference behaviour in an Ag⁺-free environment, while the built-in temperature sensor enables automatic temperature compensation when used with a compatible meter. This makes the electrode practical for users who need pH and temperature-linked measurement from one specialised electrode setup.

Important Safety Note: Hydrofluoric acid is highly hazardous. Users must confirm permitted HF concentration, exposure time, PPE, laboratory safety procedure, neutralisation method and disposal requirements before using this electrode with HF-containing samples.

Users should confirm meter compatibility, sample composition, cleaning routine and storage requirements before regular use. Strong acid and hydrofluoric acid workflows should always follow the laboratory’s approved chemical handling method.

LabChoice Australia supplies non-refillable pH / temperature electrodes for schools, universities, research laboratories, water-quality professionals and testing facilities requiring specialised pH measurement for strong acid and hydrofluoric acid-containing liquid applications.

Features

  • Non-refillable pH / temperature electrode format
  • Designed for strong acid liquid measurement
  • Designed for hydrofluoric acid-containing liquids
  • pH range listed as 0 to 12 pH
  • HF-type membrane
  • Resistant to hydrofluoric corrosion as listed in supplied information
  • Designed to minimise acidic error
  • Open junction design
  • Polymer electrolyte reference system
  • Silver Ion Trap reference system
  • Ag⁺-free reference environment
  • Supports stable reference potential over time
  • Sturdy glass membrane listed as 10 times stronger than traditional glass membranes
  • Built-in temperature sensor
  • Supports automatic temperature compensation on compatible meters
  • HF measurement condition listed as measurement time less than 1 minute
  • HF concentration should be less than 0.1 mol/L or 2000 ppm
  • Sample acid strength, HF concentration, exposure time, meter compatibility, cleaning method and storage procedure should be confirmed before ordering

Warranty

The electrode is covered for defects in material and workmanship for six months from delivery, subject to the manufacturer’s warranty terms.

The limited warranty does not cover issues caused by accidental damage, improper use, normal wear and tear, transport, storage, failure to follow product instructions, unauthorised maintenance, unauthorised modification, unauthorised repair, incompatible use with other products or materials, abuse, accidents or external causes beyond reasonable control.

Specification Details
Range 0-12 pH
Temp. Range 0 to 100°C
Membrane Type HF
Membrane Shape Hemispherical
Membrane Impedance <500MΩ
Housing Material Lead-free glass
Temp. Sensor 30KΩ NTC
Junction Open
Reference System Silver Ion Trap
Electrolyte Polymer
Length 120mm
Diameter 12mm
Connector 8-pin
Cable 3 Ft