Thermometer and Inlet Adapter with Single-Hole Rubber Cap and Ground Cone Joint, BORO 3.3 Glass

Chemical Resistant
Glass Boro
  • Laboratory inlet and thermometer adapter manufactured from BORO 3.3 glass
  • Available in three ground cone joint sizes: 14/20, 19/22 and 24/40
  • Single-hole rubber adapter accommodates compatible thermometer stems or bleed tubes
  • Ground glass cone provides a connection to matching laboratory glassware sockets
  • Borosilicate glass construction offers resistance to heat and chemical exposure
  • Removable rubber fitting allows insertion of suitable laboratory tubes or probes
  • Suitable for compatible distillation, gas inlet and temperature monitoring setups
  • Reusable laboratory glassware for chemistry, research and educational applications

View More

SKU: LC-13-TIA10130 Categories: , Brand:
Can’t see the size, capacity or variation you need? Contact our product specialists. We may be able to source, customise or manufacture the right option for your laboratory. Can’t see the size, capacity or variation you need? Contact our product specialists. We may be able to source, customise or manufacture the right option for your laboratory. Can’t see the size, capacity or variation you need? Contact our product specialists. We may be able to source, customise or manufacture the right option for your laboratory.
[request_quote_button]

Description

The Thermometer and Inlet Adapter with Single-Hole Rubber Cap and Ground Cone Joint, BORO 3.3 Glass, also known as a laboratory thermometer inlet adapter, ground glass thermometer adapter or single-hole rubber fitting adapter, is designed for inserting compatible thermometer stems or bleed tubes into laboratory glassware assemblies. Manufactured from BORO 3.3 borosilicate glass, the adapter provides resistance to thermal stress and many chemicals commonly encountered in laboratory experiments. Its glass construction makes it suitable for compatible distillation, reaction monitoring and experimental apparatus connections where a removable ground glass fitting is required. The adapter features a ground glass cone joint, designed to connect with a matching laboratory socket. This arrangement allows the adapter to be incorporated into compatible flasks, reaction vessels and other glassware assemblies while maintaining a detachable connection.

The range includes three available ground cone sizes: 14/20, 19/22 and 24/40. These variations allow users to select a suitable joint according to the dimensions of their laboratory apparatus. Ground joint sizes must match the receiving socket to ensure correct mechanical engagement and appropriate sealing. The single-hole rubber adapter provides an opening for inserting a compatible thermometer stem or bleed tube. The flexible rubber material can conform around an appropriately sized component, helping maintain its position within the adapter. The actual sealing performance depends on the rubber material, opening diameter and inserted tube dimensions. When used as a thermometer adapter, the fitting allows a suitable thermometer to pass through the rubber opening and extend into the experimental apparatus. Correct thermometer positioning is important during distillation and reaction monitoring, particularly when measuring liquid or vapour temperatures.

The adapter can also accommodate a compatible bleed tube or inlet tube for selected laboratory arrangements. The purpose of the tube depends on the experimental procedure and may involve controlled gas introduction or pressure equalisation. The assembly must not be assumed suitable for pressurised gas delivery without verified operating limits. The BORO 3.3 glass body offers resistance to many compatible laboratory chemicals, while the rubber fitting provides a flexible connection for inserted components. However, rubber has different temperature and chemical resistance properties from borosilicate glass. The rubber composition and maximum operating temperature have not been specified for these products. These adapters are suitable for compatible distillation assemblies, thermometer positioning, laboratory gas inlet arrangements and general chemistry experiments. Their removable construction allows laboratory personnel to assemble and dismantle compatible glassware systems for cleaning and reuse.

Safety Precautions: Inspect the ground glass cone and rubber fitting before use. Select a thermometer or tube that fits the rubber opening without excessive force. Avoid tightening or forcing glass components, and ensure the apparatus has appropriate pressure relief. Confirm the rubber material’s chemical and temperature compatibility before use.

LabChoice Australia supplies BORO 3.3 thermometer adapters, inlet adapters, ground glass fittings and laboratory apparatus accessories for schools, universities, research laboratories and industrial testing facilities throughout Australia.

Item Code Cone Pack of
LC-13-TIA10131 14/20 1
LC-13-TIA10132 19/22 1
LC-13-TIA10133 24/40 1