  • pH conductivity meter kit for pH, conductivity, resistivity, salinity, TDS, ORP, ion and temperature measurement workflows
  • Includes 2 channel colour touch screen meter, electrode stand, 9615S-10D pH/temp electrode and 3552-10D conductivity/temp electrode
  • Includes pH calibration solutions, conductivity calibration solutions and pH electrode filling solution
  • Two channels can be displayed simultaneously for flexible multi-parameter measurement viewing
  • Digital memory records up to 2000 measurement data sets
  • Suitable for laboratories, pharmaceutical water testing, environmental testing, industrial QC and research workflows

View More

SKU: LC-83-LF-74A-S Category: Brand:
[request_quote_button]

Description

pH Conductivity Meter Kit with ORP, Ion, TDS, Salinity and Temperature, 2 Channel Colour Touch Screen, F-74A-S, also known as a multi-parameter laboratory water quality meter kit, is designed for pH, conductivity, resistivity, salinity, TDS, ORP, ion and temperature measurement workflows in laboratories, pharmaceutical testing, environmental monitoring, industrial QC and research environments. This 2 channel colour touch screen meter set allows two channels to be displayed simultaneously, helping users monitor multiple measurement channels more clearly during routine laboratory operation. The colour touch screen interface supports clear value display, function menu navigation and practical bench workflow control.

The kit includes 2 channel colour touch screen meter, electrode stand, 9615S-10D pH/temp ToupH glass refillable electrode, 3552-10D conductivity/temp electrode, pH calibration solutions, conductivity calibration solutions and pH electrode filling solution.

The supplied meter set is listed as F-74A-S pH/COND/RES/SAL/TDS/ORP/ION/Temp Meter Set, 2 channel with colour touch screen. These inclusions support pH, conductivity, salinity, TDS, resistivity and temperature measurement setup, subject to normal calibration, electrode care and laboratory operating procedures.

Important Note: ORP electrode is not included. ORP electrode 9300-10D must be ordered separately when ORP measurement is required. Ion electrode requirements should also be confirmed separately before ordering if ion measurement will be used.

Users can switch between digital real-time graphs and analogue displays during measurement. The meter also provides on-screen support through an electronic user guide with colour pictures, including a problem solver guide for calibration and measurement. The meter supports easy navigation for main unit and electrode inspections, two-channel simultaneous display, periodic inspection mode for JIS, Pharmacopeias and Digital Simulator workflows, and customisable auto-hold function for calibration and measurement. The product information lists support for various country pharmaceutical pure water guidelines. Pharmaceutical, GLP/GMP, FDA 21 CFR Part 11 or regulatory documentation requirements should be confirmed before ordering, especially where formal compliance records are required.

Data and connectivity functions include digital memory for up to 2000 measurement data sets, USB-PC communication and USB memory support. The meter also supports simultaneous connection to GLP/GMP compatible equipment and PC for connected laboratory workflows. Multi-language support includes Japanese, English, Chinese and Korean. FDA 21 CFR Part 11 option is noted as available by quotation, so software configuration and regulatory workflow requirements should be confirmed before purchase.

LabChoice Australia supplies this pH Conductivity Meter Kit with ORP, Ion, TDS, Salinity and Temperature, 2 Channel Colour Touch Screen, F-74A-S, for schools, universities, pharmaceutical laboratories, environmental testing facilities, industrial water testing labs and research environments requiring multi-parameter measurement, two-channel operation, colour touch screen control, data recording and connectivity support.

Features

  • 2 channel colour touch screen meter design
  • Two channels can be displayed simultaneously
  • Large colour touch screen panel for clear value display and function menu navigation
  • Switches between digital real-time graphs and analogue displays during measurement
  • Full on-screen electronic user guide with colour pictures
  • Problem solver guide for calibration and measurement support
  • Easy navigation for main unit and electrode inspections
  • Periodic inspection mode: JIS, Pharmacopeias and Digital Simulator
  • Support listed for various country pharmaceutical pure water guidelines
  • Customisable auto-hold function for calibration and measurement
  • Simultaneous connection to GLP/GMP compatible equipment and PC
  • Digital memory records up to 2000 measurement data sets
  • USB-PC communication support
  • USB memory support
  • Multi-language support: Japanese, English, Chinese and Korean
  • FDA 21 CFR Part 11 option noted, quotation required
  • Electrode stand included
  • 9615S-10D pH/temp glass refillable electrode included
  • 3552-10D conductivity/temp electrode included
  • pH 4.01, pH 7.00 and pH 10.01 calibration solutions included
  • Conductivity calibration solutions included
  • pH electrode filling solution included
  • ORP 9300-10D electrode must be ordered separately when ORP measurement is required
Specification Details
pH – Measurement method Glass electorode method
pH – Measurement range pH 0.000~14.000
pH – Display range pH -2.000~20.000
pH – Resolution 0.01/0.001 pH
pH – Auto range select Yes
Repeatability ±0.001 pH±1 digit
pH – calibration point 5
pH – Repeatability check Yes
pH – Alarm limit of calibration Yes
pH – Periodical check Yes
mV(ORP) – Measurement range ±1999.9 mV
mV(ORP) – Resolution 0.1 mV
mV(ORP) – Repeatability ±0.1 mV±1 digit
Temperature – Measurement range 0.0~100.0℃(-30.0~130.0℃)
Temperature – Resolution 0.1℃
Temperature – Repeatability ±0.1℃±1 digit
ION – Measurement method Ion electrode method
ION – Measurement range 0.00 μg/L~999 g/L (mol/L)
ION – Resolution Valid numbers 3 digits
ION – Repeatability ±0.5% ±1 digit
ION – Periodical check Yes
ION – Calibration curve point 5
ION – Addition method measurement Yes
Conductivity – Measurement method 2 AC bipolar method
Conductivity – Measurement range(Display range) Cell constant 100 m-1:0.000 mS/m〜19.99 S/m
Cell constant 10 m-1:0.0 μS/m〜1.999 S/m
Cell constant 1000 m-1:0.00 mS/m〜199.9 S/m
Conductivity – Resolution 0.05% of full scale
Conductivity – Repeatability ±0.5% ±1 digit
Conductivity – Change unit Yes
Conductivity – Distilled water temperature conversion Yes
Conductivity – Periodical check Yes
Conductivity – JP/EP/USP/CP Pharmaceutical water aplication Yes
Salinity – Measurement method Conversion from conductivity value
Salinity – Measurement range(Display range) 0.00~80.00 PPT (0.000%~8.000%)
Salinity – Resolution 0.01 PPT (0.001%)
Salinity – Salt concentration calibration Yes
Resistivity – Measurement method Conversion from conductivity value
Resistivity – Measurement range (Display range) Cell constant 100 m-1:0.00 Ω・m〜199.9 kΩ・m
Cell constant 10 m-1:0.0 Ω・m〜1.999 MΩ・m
Cell constant 1000 m-1:0.000 Ω・m〜19.99 kΩ・m
Resistivity – Repeatability ±0.5%F.S.±1 digit
Resistivity – Resolution 0.05% F.S.
TDS – Measurement method Conversion from conductivity value
TDS – Measurement range (Display range) 0.01 mg/L ~1000 g/L
TDS – Resolution 0.01 mg/L
Input/output – Input(CH) 2
Input/output – USB peripherals (Communication with PC)*1 Yes
Input/output – USB host(USB memory) Yes
Input/output – RS-232C(Printer/PC) Yes
Input/output – Analog out put Yes
Data – Memory number 2,000
Data – Interval memory Yes
Data – ID input Yes
Data – Data search Yes
Display – Display Color graphic LCD with capacitive Touch Panel
Display – Dual component display Yes
Display – Multilanguage display Japanese/English/Chinese/Korean
Function – Navigation function Yes
Function – User gide Yes
Function – Graf display Yes
Function – Printer connectivity(GLP/GMP) Yes
Function – Custom printing function Yes
Function – temperature compensation(Auto/manual) Yes
Function – AutoHold function Yes
Function – AutoHold setting Yes
Function – Stability function (pH/ION) Yes
Function – Register operator Yes
Function – Security(pass word) Yes
Function – Version up function Yes
Ambient temperature 0 ℃ ~ 45℃
Power AC adaptor 100 ~ 240 V 50/60 Hz
Demensions 170(W)×174(D)×73(H)mm(Excluding electrode stand and AC adaptor)
Power consumption Approx. 9.8 VA
Mass of main unit Approx .700 g