E x p l o r e   M o r e : |
Materials: Borosilicate Glass

Viscometer, Ubbelohde Type 501-20 II, 10–100 mm²/s, Calibrated BORO 3.3 Glass

Autoclavable
Chemical Resistant
Glass Boro
  • Ubbelohde type capillary viscometer for manual viscosity measurement
  • Model listed as SI Analytics Ubbelohde 501-20 II
  • Measured range listed as 10 to 100 mm²/s
  • Maximum measured value listed as 100 mm²/s
  • Minimum measured value listed as 10 mm²/s
  • Viscometer constant listed as 0.1
  • Capillary number listed as II
  • Internal diameter listed as 1.13 mm
  • Capacity listed as 15 to 20 mL
  • Overall length listed as 290 mm
  • Standards listed as ISO 3105 and DIN 51562
  • Supplied as the selected calibrated viscometer only

View More

SKU: LC-36-VU1260 Categories: , Brand:
[request_quote_button]

Description

The Viscometer, Ubbelohde Type 501-20 II, 10–100 mm²/s, Calibrated, also known as an Ubbelohde capillary viscometer, is designed for manual viscosity measurement of compatible laboratory liquids. This SI Analytics Ubbelohde viscometer is listed as Type 501-20 II and is suitable for measuring kinematic viscosity across the listed range of 10 to 100 mm²/s. The viscometer has a listed constant of 0.1, capillary number II, internal diameter of 1.13 mm and overall length of 290 mm. The listed sample capacity is 15 to 20 mL, supporting controlled manual viscosity measurement when used with the correct bath, timing method and approved laboratory procedure.

This model is listed as calibrated and is supplied for applications requiring accurate manual viscosity testing of low to medium viscosity liquids. The listed standards are ISO 3105 and DIN 51562, supporting laboratory workflows where Ubbelohde type capillary viscometers are required according to the applicable method. This viscometer is suitable for research laboratories, industrial laboratories, quality control laboratories, university teaching laboratories and fluid analysis applications. Users should confirm the required viscosity range, capillary number, constant, calibration requirement, test temperature, sample compatibility and method requirements before ordering or use. Glass viscometers should be handled carefully. Avoid mechanical shock, sudden temperature changes, excessive force, abrasive cleaning tools and unsupported handling during filling, testing or cleaning.

This product is intended for laboratory or educational settings only and should be used under appropriate laboratory or teacher supervision. This item is supplied as the selected Ubbelohde Type 501-20 II calibrated viscometer only. Viscosity bath, timer, thermometer, stand, holder, pipette filler, liquids, cleaning accessories and additional testing equipment are not included unless specified separately.

LabChoice Australia supplies Ubbelohde Viscometers for laboratories, research facilities, quality control teams and university teaching laboratories requiring reliable capillary glassware for manual viscosity measurement.